• Free shipping over $25

  • Free help & advice

  • Open 7 days a week

TEKTELIC Kona Photon Gen-2 LoRaWAN gateway screw size

M2.5 / M4 / M5 · 8 to 25 mm long

TEKTELIC Kona Photon Gen-2 LoRaWAN gateway takes M2.5, M4 and M5 metric screws in lengths from 8 to 25 mm.

There are 3 separate fitment records for it, including M2.5 x 8mm screws for the SIM tray access-port cover (M2.5), M4 x 0.7 x 12mm ground cable lug bolt, 2.5 Nm (M4) and M5 x 0.8 machine screws in 14mm (radio to solar panel, x6), 24mm (mounting knuckle) and 25 (M5).

3 of the 3 records are marked confirmed, drawn from 1 source (tektelic.com).

An M2.5 screw is 2.5 mm in diameter with a 0.45 mm pitch, tapped with a 2.05 mm drill; imperial look-alike: #3-48 / #4-40 (2.51 / 2.84 mm) — #4-40 is the common US stand-in and it will NOT thread in.

TEKTELIC Kona Photon Gen-2 LoRaWAN gateway screw specifications

One row per fitment record. Head, drive and torque are shown only where the source states them; pitch is the ISO coarse pitch for the thread.

ThreadLengthPitchHeadDriveTorqueWhere it goesStatus
M2.58 mm0.45 mmnot statednot statednot statedM2.5 x 8mm screws for the SIM tray access-port coverConfirmed
M412 mm0.7 mmnot statednot stated2.5 NmM4 x 0.7 x 12mm ground cable lug bolt, 2.5 NmConfirmed
M514–25 mm0.8 mmnot statednot stated2.5 NmM5 x 0.8 machine screws in 14mm (radio to solar panel, x6), 24mm (mounting knuckle) and 25mm (arm to bracket), all 2.5 NmConfirmed

Fitment records and sources

M2.58mmconfirmed

M2.5 x 8mm screws for the SIM tray access-port cover

pitch 0.45 mm · tap 2.05 mm · clearance 2.9 mm · PH1 / Torx T8

M412mmconfirmed

M4 x 0.7 x 12mm ground cable lug bolt, 2.5 Nm

pitch 0.7 mm · tap 3.3 mm · clearance 4.5 mm · PH2 / Torx T20

M514-25mmconfirmed

M5 x 0.8 machine screws in 14mm (radio to solar panel, x6), 24mm (mounting knuckle) and 25mm (arm to bracket), all 2.5 Nm

pitch 0.8 mm · tap 4.2 mm · clearance 5.5 mm · PH2 / Torx T25

How to check the screw before you buy

  1. If several screws hold the same part, check that they are all the same length before assuming they are.
  2. Diameter: across the threads an M2.5 screw measures about 2.5 mm with calipers (usually a hair under). This device also uses M4 / M5, so measure each screw rather than assuming they match.
  3. Pitch: 0.45 mm from one thread crest to the next (22.22 crests per centimetre). A thread pitch gauge or the pitch-gauge tool settles it in seconds.
  4. Length: measure from under the head to the tip for pan, button, wafer and cap heads; countersunk (flat) heads are measured overall.
  5. The records span 8–25 mm, which means different positions take different lengths — match each hole to its own screw.
  6. Driver: the source does not name the drive. Standard M2.5 heads take PH1 for Phillips and T8 for Torx, and a 2 mm hex key for socket heads; a bit that fits loosely will cam out and strip the head.

Common mix-ups with M2.5 / M4 / M5

  • M2.5 pitch is 0.45mm vs M3's 0.5mm and M2's 0.4mm — forcing the wrong one strips plastic bosses instantly.
  • Water heater elements use pipe threads (NPSM/NPT), not metric machine screws.
  • Some scooters and appliances use self-tapping screws of similar diameter rather than true M5 machine threads.

Pitch gauge · Screw size finder · Torque guide

Buy these screws at TechSpare Warehouse

In stock and shipped from South Carolina. Our black screws are Phillips wafer head (low profile); match the head style and length to the original before you order.

More in Other Equipment

Browse all 125 in Other Equipment →

The same screw also fits

Devices whose records share a thread with TEKTELIC Kona Photon Gen-2 LoRaWAN gateway, closest length match first.

Questions about TEKTELIC Kona Photon Gen-2 LoRaWAN gateway screws

What size screw does TEKTELIC Kona Photon Gen-2 LoRaWAN gateway use?
M2.5 × 8 mm for M2.5 x 8mm screws for the SIM tray access-port cover; M4 × 12 mm for M4 x 0.7 x 12mm ground cable lug bolt, 2.5 Nm; M5 × 14–25 mm for M5 x 0.8 machine screws in 14mm (radio to solar panel, x6), 24mm (mounting knuckle) and 25mm (arm to bracket), all 2.5 Nm.
How long are the screws in TEKTELIC Kona Photon Gen-2 LoRaWAN gateway?
The records range from 8 to 25 mm depending on the position, so match each screw to its own hole.
What is the thread pitch of an M2.5 screw?
0.45 mm (coarse), which is the standard pitch for M2.5 machine screws; a 0.35 mm fine pitch exists but is uncommon. The tap drill is 2.05 mm and the normal clearance hole is 2.9 mm.
What screwdriver do I need for TEKTELIC Kona Photon Gen-2 LoRaWAN gateway?
The sources do not name the drive. For M2.5, Phillips heads normally take PH1 and Torx heads T8; socket heads take a 2 mm hex key.
Can I use an imperial screw instead of M2.5?
No. Imperial look-alike: #3-48 / #4-40 (2.51 / 2.84 mm) — #4-40 is the common US stand-in and it will NOT thread in. Use a true M2.5 screw so it does not cross-thread or strip the hole.
How tight should the M4 screw on TEKTELIC Kona Photon Gen-2 LoRaWAN gateway be?
The source gives 2.5 Nm for M4 x 0.7 x 12mm ground cable lug bolt, 2.5 Nm.
Where can I buy replacement screws for TEKTELIC Kona Photon Gen-2 LoRaWAN gateway?
TechSpareWarehouse (our own store) lists M2.5 x 8mm, which matches the length in the records above.