GE HealthCare Maternal Infant Care Equipment screw size
M2.5 · 8 mm long
The screws used on GE HealthCare Maternal Infant Care Equipment are M2.5, 8 mm long.
Where it is used: socket Head Cap Screw (Item No. 6600-0715-403) used in infant monitors and warmers.
Head and drive, as the source states them: socket cap head.
This entry is marked confirmed and comes from services.gehealthcare.com.
For reference, M2.5 is 2.5 mm across the threads at 0.45 mm pitch. The imperial size people confuse it with: #3-48 / #4-40 (2.51 / 2.84 mm) — #4-40 is the common US stand-in and it will NOT thread in.
GE HealthCare Maternal Infant Care Equipment screw specifications
One row per fitment record. Head, drive are shown only where the source states them; pitch is the ISO coarse pitch for the thread.
| Thread | Length | Pitch | Head | Drive | Where it goes | Status |
|---|---|---|---|---|---|---|
| M2.5 | 8 mm | 0.45 mm | Socket cap | not stated | Socket Head Cap Screw (Item No. 6600-0715-403) used in infant monitors and warmers | Confirmed |
Fitment records and sources
Socket Head Cap Screw (Item No. 6600-0715-403) used in infant monitors and warmers
pitch 0.45 mm · tap 2.05 mm · clearance 2.9 mm · PH1 / Torx T8
How to check the screw before you buy
- For a wall or arm mount, the screw has to engage the threaded insert by several turns but must not bottom out, so measure the insert depth and add the thickness of the bracket and any spacers.
- Diameter: across the threads an M2.5 screw measures about 2.5 mm with calipers (usually a hair under). If yours measures noticeably more or less, it is a different thread.
- Pitch: 0.45 mm from one thread crest to the next (22.22 crests per centimetre). A thread pitch gauge or the pitch-gauge tool settles it in seconds.
- Length: for socket cap screws, measure from under the head to the tip (countersunk heads are the exception: they are measured overall).
- The record states 8 mm. Going longer risks bottoming out or touching parts behind the hole; going shorter loses thread engagement.
- Driver: the source does not name the drive. Standard M2.5 heads take PH1 for Phillips and T8 for Torx, and a 2 mm hex key for socket heads; a bit that fits loosely will cam out and strip the head.
- Tightening: no device-specific torque is published in these records. The site's general figure for M2.5 is about 45-70 N·cm into metal threads and 20-35 N·cm into plastic bosses; snug it up and stop.
Common mix-ups with M2.5
- M2.5 pitch is 0.45mm vs M3's 0.5mm and M2's 0.4mm — forcing the wrong one strips plastic bosses instantly.
- M2.5 and M3 look the same to the naked eye — you need calipers on the shank to tell them apart.
Buy these screws at TechSpare Warehouse
In stock and shipped from South Carolina. Our black screws are Phillips wafer head (low profile); match the head style and length to the original before you order.
-
M2.5 x 8mm Screws for Retevis RT27 Radio Belt Clip 10-Pack Black Phillips
$4.99 -
M2.5 x 8mm Screws for Raspberry Pi 5 Case and PoE HAT 10-Pack Black
$4.99 -
25x M2.5 x 8mm Phillips Screws for Acer Nitro 5 LCD Hinge Assembly
$5.99 -
M2.5 x 8mm Black Wafer Head Screws for Lenovo ThinkPad X131e Chromebook Palmrest Replacement – 10-Pack Black
$4.99Choose size
More in Displays, TVs & Mounts
The same screw also fits
Devices whose records share a thread with GE HealthCare Maternal Infant Care Equipment, closest length match first.
- E-scooter dashboards & controllers also M2.5 × 8 mm
- Amazon Echo (full size) drivers also M2.5 × 8 mm
- Raspberry Pi official 7in touchscreen also M2.5 × 8 mm
- GE HealthCare/Datex-Ohmeda maternal-infant care equipment also M2.5 × 8 mm
- Compact projector internals also M2.5 × 8 mm
- Oyaide SCR-S phono cartridge screw set also M2.5 × 8 mm
- Acer Aspire 6930 also M2.5 × 8 mm
- Wurth Elektronik WA-SPAIE plastic spacer stud also M2.5 × 8 mm
Questions about GE HealthCare Maternal Infant Care Equipment screws
- What size screw does GE HealthCare Maternal Infant Care Equipment use?
- M2.5 × 8 mm for socket Head Cap Screw (Item No. 6600-0715-403) used in infant monitors and warmers.
- How long are the screws in GE HealthCare Maternal Infant Care Equipment?
- The record gives 8 mm. Measure the original from under the head (overall for a countersunk head) to confirm before ordering.
- What is the thread pitch of an M2.5 screw?
- 0.45 mm (coarse), which is the standard pitch for M2.5 machine screws; a 0.35 mm fine pitch exists but is uncommon. The tap drill is 2.05 mm and the normal clearance hole is 2.9 mm.
- What screwdriver do I need for GE HealthCare Maternal Infant Care Equipment?
- The sources do not name the drive. For M2.5, Phillips heads normally take PH1 and Torx heads T8; socket heads take a 2 mm hex key.
- Can I use an imperial screw instead of M2.5?
- No. Imperial look-alike: #3-48 / #4-40 (2.51 / 2.84 mm) — #4-40 is the common US stand-in and it will NOT thread in. Use a true M2.5 screw so it does not cross-thread or strip the hole.
- Where can I buy replacement screws for GE HealthCare Maternal Infant Care Equipment?
- TechSpareWarehouse (our own store) lists M2.5 x 8mm, which matches the length in the records above.