Agilent (HP) 8453 UV-Visible Spectroscopy System screw size

M4 · 8 mm long

Our records put Agilent (HP) 8453 UV-Visible Spectroscopy System on M4 screws, 8 mm long.

It is listed for service manual explicitly calls out 'Screw M4 x 8 mm' as a removal/replacement part in the disassembly procedure.

This entry is marked confirmed and comes from mmrc.caltech.edu.

For reference, M4 is 4 mm across the threads at 0.7 mm pitch. The imperial size people confuse it with: #8-32 (4.17 mm) — the standard US PC/rack screw, close but not the same.

Agilent (HP) 8453 UV-Visible Spectroscopy System screw specifications

One row per fitment record. Head, drive are shown only where the source states them; pitch is the ISO coarse pitch for the thread.

ThreadLengthPitchHeadDriveWhere it goesStatus
M48 mm0.7 mmnot statednot statedService manual explicitly calls out 'Screw M4 x 8 mm' as a removal/replacement part in the disassembly procedureConfirmed

Fitment records and sources

M48 mmconfirmed

Service manual explicitly calls out 'Screw M4 x 8 mm' as a removal/replacement part in the disassembly procedure

pitch 0.7 mm · tap 3.3 mm · clearance 4.5 mm · PH2 / Torx T20

How to check the screw before you buy

  1. If several screws hold the same part, check that they are all the same length before assuming they are.
  2. Diameter: across the threads an M4 screw measures about 4 mm with calipers (usually a hair under). If yours measures noticeably more or less, it is a different thread.
  3. Pitch: 0.7 mm from one thread crest to the next (14.29 crests per centimetre). A thread pitch gauge or the pitch-gauge tool settles it in seconds.
  4. Length: measure from under the head to the tip for pan, button, wafer and cap heads; countersunk (flat) heads are measured overall.
  5. The record states 8 mm. Going longer risks bottoming out or touching parts behind the hole; going shorter loses thread engagement.
  6. Driver: the source does not name the drive. Standard M4 heads take PH2 for Phillips and T20 for Torx, and a 3 mm hex key for socket heads; a bit that fits loosely will cam out and strip the head.
  7. Tightening: no device-specific torque is published in these records. The site's general figure for M4 is about 2.0-3.0 N·m into metal threads and 0.8-1.4 N·m into plastic bosses; snug it up and stop.

Common mix-ups with M4

  • Ideal Scope Mounting System manuals disagree between revisions (M4 vs M5 clamping screws) - check your own manual.
  • goBILDA is metric M4; the older Actobotics/ServoCity system it resembles is imperial 6-32. The parts look alike and will strip each other.

Pitch gauge · Screw size finder · Torque guide

More in Standards & References

Browse all 31 in Standards & References →

The same screw also fits

Devices whose records share a thread with Agilent (HP) 8453 UV-Visible Spectroscopy System, closest length match first.

Questions about Agilent (HP) 8453 UV-Visible Spectroscopy System screws

What size screw does Agilent (HP) 8453 UV-Visible Spectroscopy System use?
M4 × 8 mm for service manual explicitly calls out 'Screw M4 x 8 mm' as a removal/replacement part in the disassembly procedure.
How long are the screws in Agilent (HP) 8453 UV-Visible Spectroscopy System?
The record gives 8 mm. Measure the original from under the head (overall for a countersunk head) to confirm before ordering.
What is the thread pitch of an M4 screw?
0.7 mm (coarse), which is the standard pitch for M4 machine screws; a 0.5 mm fine pitch exists but is uncommon. The tap drill is 3.3 mm and the normal clearance hole is 4.5 mm.
What screwdriver do I need for Agilent (HP) 8453 UV-Visible Spectroscopy System?
The sources do not name the drive. For M4, Phillips heads normally take PH2 and Torx heads T20; socket heads take a 3 mm hex key.
Can I use an imperial screw instead of M4?
No. Imperial look-alike: #8-32 (4.17 mm) — the standard US PC/rack screw, close but not the same. Use a true M4 screw so it does not cross-thread or strip the hole.