Straumann Axiom TL Plural Dental Implant screw size
M1.6 · length not stated in the sources
If you are replacing a screw on Straumann Axiom TL Plural Dental Implant, the thread is M1.6. None of the sources we found gives an exact length, so measure the original before you order.
It is listed for laboratory screw for TL plural Angled Access (REF TSAA163P-2).
This entry is marked confirmed and comes from shop.straumann.com.
For reference, M1.6 is 1.6 mm across the threads at 0.35 mm pitch. The imperial size people confuse it with: #1-72 UNF (1.85 mm) is larger; there is no true imperial equivalent.
Straumann Axiom TL Plural Dental Implant screw specifications
One row per fitment record. Head, drive are shown only where the source states them; pitch is the ISO coarse pitch for the thread.
| Thread | Length | Pitch | Head | Drive | Where it goes | Status |
|---|---|---|---|---|---|---|
| M1.6 | not stated | 0.35 mm | not stated | not stated | Laboratory screw for TL plural Angled Access (REF TSAA163P-2) | Confirmed |
Fitment records and sources
Laboratory screw for TL plural Angled Access (REF TSAA163P-2)
pitch 0.35 mm · tap 1.25 mm · clearance 1.8 mm · PH00 / Torx T4–T5
How to check the screw before you buy
- For a wall or arm mount, the screw has to engage the threaded insert by several turns but must not bottom out, so measure the insert depth and add the thickness of the bracket and any spacers.
- Diameter: across the threads an M1.6 screw measures about 1.6 mm with calipers (usually a hair under). If yours measures noticeably more or less, it is a different thread.
- Pitch: 0.35 mm from one thread crest to the next (28.57 crests per centimetre). A thread pitch gauge or the pitch-gauge tool settles it in seconds.
- Length: measure from under the head to the tip for pan, button, wafer and cap heads; countersunk (flat) heads are measured overall.
- Driver: the source does not name the drive. Standard M1.6 heads take PH00 for Phillips and T4–T5 for Torx, and a 1.5 mm hex key for socket heads; a bit that fits loosely will cam out and strip the head.
- Tightening: no device-specific torque is published in these records. The site's general figure for M1.6 is about 12-20 N·cm into metal threads and 6-10 N·cm into plastic bosses; snug it up and stop.
More in Displays, TVs & Mounts
The same screw also fits
Devices whose records share a thread with Straumann Axiom TL Plural Dental Implant, closest length match first.
- Ritter Implants angled prosthetic screw also M1.6
- Dell Pro 14 Plus portable monitor (P1425) also M1.6
- Lenovo Yoga Slim 7 14AKP10 also M1.6
- Dell Alienware x17 R2 also M1.6
- Dell Latitude 7520 also M1.6
- Dell Inspiron 17 7706 2-in-1 also M1.6
- Dell Latitude 9440 2-in-1 also M1.6
- Dell Pro Max 14 MC14250 also M1.6
Questions about Straumann Axiom TL Plural Dental Implant screws
- What size screw does Straumann Axiom TL Plural Dental Implant use?
- M1.6 for laboratory screw for TL plural Angled Access (REF TSAA163P-2).
- How long are the screws in Straumann Axiom TL Plural Dental Implant?
- None of the sources states a length. Remove one screw and measure it from under the head to the tip (overall for a countersunk head).
- What is the thread pitch of an M1.6 screw?
- 0.35 mm (coarse), which is the standard pitch for M1.6 machine screws; a 0.2 mm fine pitch exists but is uncommon. The tap drill is 1.25 mm and the normal clearance hole is 1.8 mm.
- What screwdriver do I need for Straumann Axiom TL Plural Dental Implant?
- The sources do not name the drive. For M1.6, Phillips heads normally take PH00 and Torx heads T4–T5; socket heads take a 1.5 mm hex key.
- Can I use an imperial screw instead of M1.6?
- No. Imperial look-alike: #1-72 UNF (1.85 mm) is larger; there is no true imperial equivalent. Use a true M1.6 screw so it does not cross-thread or strip the hole.